PLC-048: Swing out rotor, 32 tubes x 15ml., RPM/RCF display, include tube holders.
- Ideal for General purpose and PRP in hospital.
- RoHS, REACH compliant.
- Imbalance alarm & stop and Safety Interlocking and shutout system.
- Brushless DC drive motor, maintenance free.
- Manual override lets you open lid in case of power failure.
- Automatic braking system brakes to complete stop gently in 30 seconds when the set time is elapsed, preventing test tubes from breaking or specimens from remixing.
- Module microprocessor-based circuit board ensures excellent performance and easy for maintenance.
- Safety interlocking system. LID can’t be opened while rotor is spinning unless the set time has elapsed.
- Transparent viewfinder on top of lid to view the rotor spinning without opening LID.
Clinical or other purpose. Used mainly in the clinical laboratory to separate the components of suspensions through low- or medium-speed centrifugal force. If relevant, all levels of health care with laboratory. Ideal use in clinical laboratory, histology, haematology, immunology, microbiology, pathology, serology and toxicology. This centrifuge provides a desired testing within the range of 1000 ~ 3500rpm for different test tubes containing diagnostic specimens for blood separation of Red blood cell, Leucocytes, plasma, serum, platelet, urine etc. for qualitative or quantitative test procedures. Then proceed with the further diagnostic examinations and checkup for general purpose, PRP, or the related disease syndrome of the patients.
- Overall dimension |
: 480 x 590 x 380mm approx. (±5mm) |
- Control |
: Microprocessor controlled system |
- N.W. / G.W. |
: 49.0 / 56.0 kg approx. (±0.5kg) |
- RPM / RCF |
: Automatic conversion |
- Speed range |
: LED 4-digit, 1000 ~ 3500 rpm |
- Speed increment |
: 100 rpm |
- Maximum RCF |
: Maximum fixed at 2328 x g |
- Maximum volume |
: 800 ml (16 x 50ml) or (8 x 100ml) |
- Timer (LED digital) |
: 0 ~ 99 min adjust. 1 min increment |
- Emergency STOP |
: Yes |
- ERROR detection |
: Yes (5 errors detection) |
- Motor |
: Brushless DC motor, DC315V, 600W |
- Power supply |
: 115V or 230V (±10%), 50/60Hz |
- Chamber |
: Stainless steel #304 |
Catalog # |
: Volume |
: Tube Holders Size |
- SW-1580 |
: 1.5/2.0ml x 80 tube |
: Ø11 x 30 mm (D.) |
- SW-0548 |
: 5 ~ 10ml x 48 tube |
: Ø17.2 x 58 mm (D.) |
- SW-1532 |
: 10 ~ 15ml x 32 tube |
: Ø17.6 x 73.2mm (D.) |
- SW-5016 |
: 50 ml x 16 tube |
: Ø30.0 x 73.2mm (D.) |
- SW-1008 |
: 100ml x 8 tube |
: Ø40.0 x 170mm (D.) |
Product Name | Universal Centrifuge model PLC-048 |
---|---|
Apply Add To Quote | Oui |
Small | /1/_/1_21.jpg |
Champ d'application | Pour laboratoire au sein d’hôpitaux / école, vétérinaire, biochimie, banque de sang, industrie. |
Vitesse max. (rpm) | 1000 à 3500 tr / min |