PLC-036H: RoHS, Brush-less motor, multi-voltage 100-240V, adjustable 500-15000rpm
- RPM / RCF conversion automatically.
- Universal voltage 100V ~ 240V, 50/60Hz.
- Power stabilizer: 88V ~ 264V preventing power surge accidently.
- General Purpose and also available for PRP & PRF purpose.
- Rotor recognized function for an accurate RCF.
- In case of power failure, just pull wire to open LID.
Clinical or other purpose. Used mainly in the clinical laboratory to separate the components of suspensions through low- or medium-speed centrifugal force. If relevant, all levels of health care with laboratory. Ideal use in clinical laboratory, histology, haematology, immunology, microbiology, pathology, serology and toxicology.
- ERROR detection including rotor imbalance detection & alarm.
- Electronic interlocking lid safety device.
- Versatile rotors for selection, interchangeable.
- Automatic braking system at the end of run. Emergency STOP.
- Microprocessor-based control system.
- Stainless steel interior chamber.
- Unless lid is locked, the motor can’t spin.
- Overheating sensor detects temperature of motor and driver.
- A transparent viewfinder on top easy for you to monitor the rotor spinning.
- Module microprocessor-based circuit board ensures excellent performance and easy for maintenance.
- Model |
: PLC-036H |
- Overall dimension |
: 320 x 400 x 310mm approx. |
- Net weight |
: 17 kg (not include rotor) or 43.18 lbs. |
- Motor Drive |
: Brushless, DC24V, 153W |
- Chamber |
: Stainless steel easy for cleaning |
- Rotor type |
: Various (Interchangeable) |
- Speed indicator |
: LED digital |
- Speed control |
: Microprocessor |
- Timer |
: 2-digits, 99 min. LED digital |
- Power source |
: Universal 100V ~ 240V, 50/60HZ |
- Speed (rpm) |
: 1000 ~ 15,000rpm |
- RPM / RCF conversion |
: Yes |
- Imbalance detection |
: Yes, alarm & brake |
- Brake |
: Automatic braking system |
- Safety interlocking lid |
: Yes |
- Lid open (Power failure) |
: Yes, fingers pull wire (Tool no need) |
- Overheat alarm |
: Yes |
- Emergency STOP |
: Yes, lid lock release |
- Safety shutout device |
: Yes, when lid is open |
- ERROR detection |
: Yes (5 Errors). |
Rotor |
Tubes x No. |
Suggested Max RPM / RCF |
- A-1820 |
: 1.5ml (or 2.0ml) x 18 |
: 14,000 rpm / 16,083 xg |
- A-2420 |
: 1.5ml (or 2.0ml) x 24 |
: 15,000 rpm / 20,630 xg |
- A-3202 |
: 0.2ml x 32 (micro-plate) |
: 15,000 rpm / 15,659 xg |
- A-0815 |
: 15 (or 10)ml x 8 tubes |
: 5,000 rpm / 2,929 xg |
- A-1215 |
: 15 (or 10)ml x 12 tube |
: 5,000 rpm / 3,172 xg |
- A-2405 |
: 5 ml x 24 tubes |
: 5,000 rpm / 2,865 xg |
- H-0450 |
: 50 ml x 4 tubes |
: 5,000 rpm / 3,284 xg |
- A-1550 |
: (50 ml + 15ml) x 4 tubes |
: 4500 rpm / 2513 or 2490 x g |
- F-2415 (for HCT) |
: 0.75ml x 24 tubes 24 apillary tubes |
: 15,000 rpm / 22,640 xg or 12,000 rpm / 14,490 xg or 13,000 rpm / 17,005 xg |
NOTE: All measurements are subject to tolerance within range ±5%
Product Name | Universal Centrifuge model PLC-036H |
---|---|