Air convection: natural convection or forced convection.
A device heated by electrical currents passing through a heating block containing simple resistors for the purpose of growing micro-organisms and cells that required oxygen for growth. Aerobic incubators are typically used for serology and crystallization studies, tissue culture works, paraffin embedding and in vitro fertilization.
- Heavy-duty glass fiber insulation sustains to prevent the heat loss and maximize energized efficiency.
- Double wall of exterior steel treated by powder coating ensuring scratch free and corrosion free.
- The height of stainless steel mesh shelf is adjustable.
- A tempered glass window on front door is easy for monitoring specimens, which does not required to open the outer door so as to prevent from the disturbing the samples.
Model |
: IN-601 (Analog) |
: IN-601 (Digital) |
- Capacity (liter,wattage) |
: (16L,350W) ; (34L,350W) ; (53L,350W) ; (75L,350W) ; (90L,500W) ;(110L,500W) |
: (16L,350W) ; (34L,500W) ; (53L,500W) ; (75L,500W) ; (90L,750W) ;(110L,750W) |
- Chamber |
: Stainless steel SUS#304 |
: Stainless steel SUS#304 |
- Temperature range |
: Ambient + 5ºC to 75ºC |
: Ambient + 5ºC to 75ºC (Adjustable) |
- Control system control |
: Analog |
: Microprocessor PID controlled system |
- Temperature display |
: Mercurial thermometer |
: Digital LED |
- Sensor |
: Hydraulic expanded |
: PT-100 |
- Standard Accessory |
: 2 stainless steel shelves |
: 2 stainless steel shelves, interval is adjustable |
- Timer |
: Mechanical, 180min + HOLD |
: Mechanical, 180min + HOLD |
- Temperature setting, Display |
: Analog / Thermometer |
: Digital LED |
- Temperature uniformity |
: ±4ºC at 37ºC |
: ±2ºC at 37ºC |
- Temperature stability |
: ±3ºC at 37ºC |
: ±0.1ºC at 37ºC |
- Resolution |
: 1ºC |
: 0.1ºC |
- Over-heat alarm & shutout |
: Yes, At 80ºC |
: Yes, 4ºC above the set point |
- Air convection |
: Natural convection |
: Forced convection |
- Air vent |
: Yes |
: Yes |
- Quality standard |
: ISO, CE, GMP, FDA, Japan |
: ISO, CE, GMP, FDA, Japan |
- All measurements are approximate, the allowance is acceptable.
- Other capacities are available subject to the minimum quantity up to 5 units, such as 150L, 200L, 250L etc.
- IN-601 is designed when the cost is the major consideration to the users. Natural convection is used when the accurate temperature control and uniformity are not critical important to users and your samples can’t be disturbed by air current.
- Function preheating with timer working only when the actual temperature at 2ºC below set point.
- Safety devices:
1- Over temperature alarm and shutout device to 4ºC above the set point.
2- Sophisticated design to shut off power protecting sterilizer from excessive heating at 75ºC if primary control fails.
3- Audible & visible alarm indicated by indicator.
4- Timer stop counting when PV is 5ºC below SV after stabilization if door is opened, the memory will store the past time and start to count when the PV value returns to 2ºC below SV.