Description

The SIBELSOUND 400, is a revolutionary two-channel audiometer. The entire system is controlled by Digital Signal Processor (DSP) for reliable, quick and easy audiometric exploration of hearing thresholds and screening tests, such as suprathreshold pure tone tests.

Guarantee extension

08310 Guarantee extension of SIBELSOUND 400 (1 year)

Tests

02558 Pure threshold audiometry by bone conduction 
02559 Pure tone threshold audiometry by free field (Speakers included) 
00807 Speech Audiometry SIBELSOUND 400 A/AM/AOM (Intercom included)
02557 High frequency audiometry SIBELSOUND 400 AOM/AOM+/SUPRA Includes HDA 300 headphones
00763 Frequency modulation and amplitude modulation SIBELSOUND 400 AOM/AOM+

Options and accessories

00753 Internal data base for more than 1000 test SIBELSOUND 400 A/AM
01507 Carrying bag SIBELSOUND 400
03658 USB Cable type A-B 2.0 Datospir Touch, SIBELSOUND 400
01807 Patient Response SIBELSOUND 400; AS5; AC50
07029 Intercom / Monitor SIBELSOUND 400 A/AM/AOM (Includes micro patient & doctor's headphones)
02214 Audiometric Test Booth Interconnection (1u.)
02260 Air Conduction Set AS5, AC50, SIBELSOUND 400
02258 Bone Conduction Set AS5, AC50, SIBELSOUND 400
03078 Sound suppressors for air conduction (Audiocups) SIBELSOUND 400, AS5, AC50
01831 Serial-USB adaptor 1

Main Features

  • Advanced digital technology based on DSP
  • Calculation of hearing loss and diagnosis
  • Internal database > 1000 tests
  • Suprathreshold tests
  • High frequency
  • Musical frequencies
  • Automatic masking
  • Connectivity with other management systems (EMR – Electronic Medical Record)
  • Customizable

Communications

One of the great qualities of the SIBELSOUND 400, is a communications system with other equipment that allows it to:

  • Print directly to a USB printer
  • Transfer information from the unit’s internal database to a PC
  • Communicate with a PC in real time
  • Export patient tests to other management systems (EMR)
  • Update the unit’s internal firmware

Using the appropriate software, communications can be established through two different channels:

  • USB (standard)
  • RS232C Serial (optional)

Technical Specifications

  • Channels: Two
  • Functional specifications: See tables of models and frequencies
  • Transducers: TDH39 – HDA200 – B71 (depending on the model)
  • Screen: LCD alphanumeric backlighted 2 X 16 Protection: Time restricted high frequency signals to protect both patient and unit
  • Self-check: Automatically checks the status of the audiometer
  • Unit test: Allows the user or technician to check the condition of certain functions or components
  • Custom settings: Programme to personalise the audiometer according to the needs of the user
  • Calibrations: Equipped with calibrations according to ISO and ANSI
  • Safety standards: EN60601-1, EN60601-1-1, EN60601-1-2, EN60601-1-4
  • Audiometry standards: IEC60645-1, IEC60645-2, IEC60645-4
  • Calibration standards: EN ISO 389-1, EN ISO 389-3, EN ISO 389-4, EN ISO 389-5, EN ISO 389-7, ANSI S3.6-2004
  • Working temperature: 10 to 40 ºC
  • Relative humidity: <90% (no condensation)
  • Power supply: 100 to 240V ±10% / 50/60 Hz ±3%
  • Dimensions: 390 mm x 260 mm x 105 mm
  • Weight: 2.4 kg without accessories
  • Standard accessories: Depending on the model
  • Optional accessories: Depending on the model

Configurations table

CONFIGURATION ACCORDING TO MODEL

AM

Two channels

Included

Pure tone threshold audiometry by air conduction

Included

Pure tone threshold audiometry by bone conduction

Optional

Pure tone threshold audiometry by free field

Optional

Pure tone suprathreshold audiometry (SISIGRAM)

Optional

Pure tone suprathreshold audiometry (Fowler-ABLB, Tone Decay, Weber, Lüscher, etc.)

Optional

Speech audiometry

Optional

High frequency audiometry

Not included

Masking with narrow band noise

Included

Masking with white noise

Included

Masking with speech noise

Optional

Synchronized masking

Included

Intermediate frequencies: 125, 750, 1500 Hz

Optional

Musical frequencies

Optional

Selection of exploration frequencies

Included

Continuous and pulse tone

Included

Pulse/alternating tone and modulating/alternating tone

Optional

Reference tone (1 dB)

Not included

Frequency modulation and amplitude modulation

Not included

Calculation of hearing loss

Included

Diagnosis (COUNCIL, IMSS MEXICO, ELI, SAL, KLOCKHOFF, MOH, others…)

Included

Internal database for more than 1000 tests

Optional

Intercom / Monitor

Optional

USB and parallel connections to external printer

Included

USB computer connection

Included

RS232 computer connection

Optional

Audiometry software (Demo)

Included

Audiometry software (Licence)

Optional

Sound suppressors for air conduction

Optional

External printer

Optional

User manual and quick user guide

Included

Carrying bag

Optional

Audiometer type according to IEC60645

4

Plus d’information
Product Name Audiometer SIBELSOUND 400 - AM
Apply Add To Quote Oui
Small /7/4/74782-169461_1.jpg
Technologie de l'audiomètre Digitale
Rédigez votre propre commentaire
Vous commentez :Audiometer SIBELSOUND 400 - AM
Vendu par
Sibelmed
0 / 5
0% Avis positif (0 ratings)
Prix :
 (0/5)
Valeur :
 (0/5)
Quality :
 (0/5)